Honeywell S9200U1000 Hot Surface Control, Universal Ignition Integrated Review
Honeywell S9200U1000 Hot Surface Control, Universal Ignition Integrated Feature
- Main burner ignition using a 120V hot surface igniter
- Flame rectification circuit to monitor flame presence
- Monitoring of system pressure switch, high temperature limit, and rollout functions
- Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat
- LED system status, performance and diagnostic indication
The Honeywell S9200U1000 universal hot surface ignition integrated furnace control is used to regulate a standard induction-type circulating fan motor.